Application of Dolycon CT100 Series Inverter in Pile driver
 
With the development of different technical requirements, the rotary digging pile driver can no longer meet the customer's requirements. The customer needs to transform the rotary digging pile driver into a rotary jet pile driver. In addition to the transformation of the mechanical part, the electrical part needs to be reconstructed synchronously.
First, remove the original cam controller and electrical control, add a new frequency conversion control cabinet, remove the brush part of the winding motor, and short-circuit the rotor of the motor.
 
Control principle: The brake motor turns on when the winch motor is working to 10HZ, brakes when it is lower than 10HZ, the winch motor is controlled through the external terminal, and the multi-speed control is used.
 
Parameters setting as follow:

Function code

Function description

Parameter setting

Note

F00.00

Control mode selection

1

vector control mode

F00.01

Run command channel

1

Terminal running

F00.02

Main frequency setting

6

Multi-step speed setting

F00.14

ACC time 0

-

 

F00.15

DEC time 0

-

 

F01.02

Rated power

-

Set according to the nameplate of motors to ensure accurate self-learning parameters 

F01.03

Rated frequency

-

F01.04

Rated speed

-

F01.05

Rated voltage

-

F01.06

Rated current

-

 

F01.12

Motor parameter auto-tuning

2

Static auto-tuning

F06.01

DI1 terminal function

1

FWD run command

F06.02

DI2 terminal function

2

REV run command

F06.03

DI3 terminal function

16

Multi-step speed 1

F06.04

DI4 terminal function

17

Multi-step speed 2

F06.05

DI4 terminal function

18

Multi-step speed 3

F06.06

DI4 terminal function

19

Multi-step speed 4

F07.03

Relay T1 output

3

Frequency level detection FDT output

F11.00

Multi-step speed command 1

-

 

F11.01

Multi-step speed command 2

 

 

F11.02

Multi-step speed command 3

 

 

F11.03

Multi-step speed command 4

 

 

F13.03

ACC time 1

-

 

F13.04

DEC time 1

-

 

F13.05

ACC time 2

-

 

F13.06

DEC time 2

-

 

F13.07

ACC time 3

-

 

F13.08

DEC time 3

-

 

F13.10

FDT level detection value

10Hz

 

 